Problem
|
|
Possible Cause
|
|
Possible Solution
|
 |
|
Motor overload of vacuum pump
|
|
Too much water is being supplied to the pump
|
|
Adjust water supply untill maximum vacuum is achieved with minimum water supply
|
 |
|
|
|
Current draw exceeds power of motor
|
|
Check the motor data tag
|
 |
|
|
|
Too less water is being supplied to the pump
|
|
Adjust water supply untill maximum vacuum is achieved with minimum water supply
|
 |
|
|
|
The exhaust line has a restriction or is not connected to a vent open to the atmosphere
|
|
Unclog the line / connect it to an open vent
|
 |
|
Vacuum too low
|
|
Water too warm
|
|
Adjust water temperature (cold water produces more vacuum)
|
 |
|
Barrel Heat Zone will not reach the set point
|
|
Heater band burned out
|
|
Replace heater band
|
 |
|
|
|
Pyrometer is not energized when the temperature drops below the set point
|
|
Replace the pyrometer
|
 |
|
|
|
Mercury contactor in control cabinet not energized or faulty
|
|
Replace mercury contactor
|
 |
|
|
|
Overload protection circuit breaker for the individual heater zone is not energized
|
|
Energize circuit breaker for appropriate zone
|
 |
|
|
|
Thermocouple is not seated in the thermocouple well
|
|
Seat the thermocouple well again
|
 |
|
|
|
Thermocouple or heater bands reversed at their zones (Example: Zone 2 thermocouple sensing a low temperature in Zone 2 and adding heat to Zone 1
|
|
Switch thermocouple or heater band to the proper zone
|
 |
|
|
|
Cooling control solenoid stuck in the open position
|
|
Replace control solenoid
|
 |
|
Heat zone overriding the set point
|
|
Pyrometer does not de-energize when the temperature exceeds the set point
|
|
Replace the pyrometer
|
 |
|
|
|
Pressure relief valve stuck in the open position
|
|
Replace the relief valve
|
 |
|
|
|
Thermocouple or heater bands reversed at their zones (Example: Zone 2 thermocouple sensing a low temperature in Zone 2 and adding heat to Zone 1
|
|
Switch thermocouple or heater band to the proper zone
|
 |
|
|
|
Insufficient water flow through the heat exchanger. Heat exchanger is clogged or the globe valve is closed
|
|
Check hoses, unclog heat exchanger or open globe valve. Replace heat exchanger
|
 |
|
|
|
Solenoid for zone's fluidcontrol not opening
|
|
Replace defective solenoid
|
 |
|
|
|
Defective pump, motor, thermal overload or coupling
|
|
Replace defective pump, motor or coupling
|
 |
|
|
|
Oil system plugged or clogged
|
|
Change oil filter. Clean and flush oil systems
|
 |
|
Screw temperature will not reach the set point
|
|
Heater band is burned out
|
|
Replace the heater band
|
 |
|
|
|
Thermocouple is defective
|
|
Replace the thermocouple
|
 |
|
|
|
Pyrometer : Not energizing the mercury contactor
|
|
Replace the pyrometer
|
 |
|
|
|
Cooling solenoid continuously energized
|
|
Replace the solenoid
|
 |
|
|
|
Mercury contactor is defective
|
|
Replace the mercury contactor
|
 |
|
|
|
Cooling fluid solenoid valve is stuck open
|
|
Replace the solenoid valve
|
 |
|
|
|
Insufficient fluid flow: clogged filter
|
|
Change the filter
|
 |
|
|
|
Faulty pump, motor or coupling
|
|
Replace
|
 |
|
|
|
Oil system plugged or clogged
|
|
Change oil filter. Clean and flush oil system
|
 |
|
Screw temperature overriding the set point
|
|
Pyrometer does not deenergize when the temperature exceeds the set point
|
|
Replace the pyrometer
|
 |
|
|
|
Thermocouple near the flow meter outlet is defective
|
|
Replace the thermocouple
|
 |
|
|
|
Insufficient water flow through the heat exchanger
|
|
Unclog or replace heat exchanger
|
 |
|
|
|
Water solenoid supply not energized or stuck in the close position
|
|
Replace the solenoid
|
 |
|
|
|
Cooling fluid solenoid valve stuck closed
|
|
Replace solenoid valve
|
 |
|
|
|
Pressure relief valve stuck open
|
|
Replace relief valve
|
 |
|
|
|
Filter clogged
|
|
Change filter
|
 |
|
|
|
Faulty pump, motor, thermal, overload or coupling
|
|
Replace
|
 |
|
|
|
Oil system plugged or clogged
|
|
Change oil filter. Clean and flush oil system
|
 |
|
Insufficient vacuum for venting
|
|
Insufficient water flow
|
|
Check hose
|
 |
|
|
|
|
|
Check hose clamps and manifold bolts for tightness
|
 |
|
|
|
|
|
Check O-rings in sight glass
|
 |
|
|
|
|
|
Clean out gate valve
|
 |
|
|
|
|
|
Change the filter
|
 |
|
|
|
|
|
Check solenoid valve
|
 |
|
|
|
|
|
Check pump, motor and coupling
|
 |
|
Excessive vibration
|
|
Poor coupling alignment at motor
|
|
Realign coupling
|
 |
|
|
|
Defective bearing in the reduction gearbox
|
|
Replace the bearing
|
 |
|
|
|
Defective bearing in the motor
|
|
Replace the bearing
|
 |
|
Thumping noise in the rear of the machine
|
|
Defective bearing in the distributor gearbox
|
|
Replace defective bearing
|
 |
|
|
|
Rough spot on gear inside distributor gearbox
|
|
Remove rough spot on gear
|
 |
|
|
|
Poor coupling alignment between the reduction and distributor gearboxes
|
|
Realign coupling
|
 |
|
Erratic drive RPM
|
|
Faulty speed board in DC drive
|
|
Replace speed board
|
 |
|
|
|
Faulty current board in DC drive
|
|
Replace current board
|
 |
|
|
|
Faulty input voltage to DC drive
|
|
Correct the voltage supply
|
 |
|
|
|
Excessive current being drawn from the drive
|
|
Check / Replace DC drive motor
|
 |
|
Starve feeder auger does not operate
|
|
The reference potentiometer is set to zero
|
|
Reset or replace the potentiometer
|
 |
|
|
|
The control is not receiving the start input due to debris in the start button
|
|
Clean out control buttons
|
 |
|
|
|
The starting coil has not received an output from the control or is faulty
|
|
Check the connection and/or replace the starting coil
|
 |
|
|
|
The drive fuses have blown
|
|
Replace the fuses
|
 |
|
|
|
The feeder drive is faulty
|
|
Replace the motor
|
 |
|
|
|
The armature fuse has blown
|
|
Replace the fuse
|
 |
|
|
|
Optional signal conditioned card used for slaving the main extruder motor and the feed auger has failed
|
|
Replace the card
|
 |
|
Starve feeder auger operates but will not achieve full speed
|
|
Main motor potentiometer is set low or to zero
|
|
Increase the setting of the main motor potentiometer
|
 |
|
The entire extruder is overheating
|
|
The water saver solenoid has failed in the closed position or blown in related fuse
|
|
Check the solenoid valve and/or replace the fuse
|
 |
|
|
|
The cooling water supply to the extruder is dirty causing restricted flow or the supply pressure is insufficient
|
|
Change the filter or check the supply line for leaks
|
 |